7. Troubleshooting
C315A0
Self-test failed
to
C315A23
C316A
MCU
C316A0
Unknown ID
C316A1
This version of the
firmware is obsolete
and needs to be
updated
C317A0
Failure injection
C317A1
Failure injection
C317A2
Failure injection
C317A3
Failure injection
C318A0
Stack monitor
C319A0
Filesys Diagnostic
Tool
C319A1
Filesys Diagnostic
Tool
C319A2
Filesys Diagnostic
Tool
C319A3
Filesys Diagnostic
Tool
C319A4
Filesys Diagnostic
Tool
C319A5
Filesys Diagnostic
Tool
C319A6
Filesys Diagnostic
Tool
Service Manual
The system watchdog is not
working as expected
Micro Control Unit
The Microcontroller
Identifier does not match an
expected value. Firmware
does not match hardware.
The firmware in the robot is
too old and needs to be
updated
Injecting type unexpected
Missing handler for
specified type
Invalid data provided to
specified type
Throw report
The stack level watermark
is breached
Read operation started, at
specified start address
Read operation was
succesfully completed
Read operation failed, due
to illegal address
Received data for
unexpected address
Unxpected address
Erased sector at specified
address
Write operation was
succesfully completed
189
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
UR3