C200A9
3V3A power good pin
is low
C200A10
3V3B power good pin
is low
C200A11
5V power good is
low
C200A12
3V3 voltage too low
C200A13
3v3 voltage too high
C200A14
48V input is too low
C200A15
48V input is too high
C200A16
24V IO short
circuited
UR3
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Too high current
134
7. Troubleshooting
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) Check 48 V Power supply,
current distributer, energy
eater and Control Board for
issues
a) Do a Complete rebooting
sequence.
b) Check 48 V Power supply,
current distributer, energy
eater and Control Board for
issues
a) Do a Complete rebooting
sequence.
b) Disconnect external I/O
connections and check
external power supply if
connected