Universal Robots UR3 Service Manual page 201

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

7. Troubleshooting
C499A2
Actual position has
a an error and isn't
final. Position error
C499A3
Target position
C499A4
Actual average
position
C499A5
Actual position
variance
C499A6
Actual position min
to max delta
C499A7
Actual sample
position number
C720A2
LVD (low voltage
detection)
C710A
ROM Test
C710A0
Critical error
C710A1
ROM corrupted
C710A2
Failed to validate
CRC on invariant
data in RAM
C710A3
Unexpected size of
invariant data
C710A4
Failed to validate
CRC on code
segment in RAM
C720A
Low Voltage
Detection (LVD)
Service Manual
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Low Voltage warning level
reached
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
195
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C720A
 a) Do a complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
Same as C710A
Same as C710A
Same as C710A
Same as C710A
Same as C710A
a) Do a Complete rebooting
sequence
b) Check for loose
connections
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
UR3

Hide quick links:

Advertisement

Table of Contents
loading