Safety Parameter Of The Tm54F - Siemens SINAMICS G130 Manual

Safety integrated
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

10.4.2.3

Safety Parameter of the TM54F

Table 10- 7
SI function
Sampling time
Wait time for test stop on DO
Monitoring time discrepancy
Forced dormant error detection timer p10003
Acknowledging internal event input
terminal
Input terminal
forced dormant error detection
Assignment of drive objects
Assignment of drive groups
Digital inputs debounce time
STO input terminal
SS1 input terminal
SS2 input terminal
SOS input terminal
PLC input terminal
SLS_Limit(1) input terminal
Safety Integrated
Function Manual, 05/2010, A5E03264275A
Parameter for control via the TM54F (excerpt)
Acceptance test and acceptance report
Parameter
p10000
p10001
p10002
p10006
p10007
p10010[0]
p10010[1]
p10010[2]
p10010[3]
p10010[4]
p10010[5]
p10011[0]
p10011[1]
p10011[2]
p10011[3]
p10011[4]
p10011[5]
p10017
p10022[0]
p10022[1]
p10022[2]
p10022[3]
p10023[0]
p10023[1]
p10023[2]
p10023[3]
p10024[0]
p10024[1]
p10024[2]
p10024[3]
p10025[0]
p10025[1]
p10025[2]
p10025[3]
p10026[0]
p10026[1]
p10026[2]
p10026[3]
p10027[0]
p10027[1]
p10027[2]
p10027[3]
10.4 Acceptance report
Value
12.00 ms
500.00 ms
12.00 ms
8.00 h
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1.00 ms
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
261