Overview Of Important Parameters - Siemens SINAMICS G130 Manual

Safety integrated
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Safety Integrated Extended Functions
6.4 Safe Stop 1 (SS1)
6.4.3

Overview of important parameters

● p1135[0...n] OFF3 ramp-down time
● p9301 SI Motion enable safety functions (Motor Module)
● p9501 SI Motion enable safety functions (Control Unit)
● p9306 SI Motion function specification (Motor Module)
● p9506 SI Motion function specification (Control Unit)
● p9360 SI Motion pulse cancelation shutdown speed (Motor Module)
● p9560 SI Motion pulse cancelation shutdown speed (Control Unit)
● r9722.0...15 CO/BO: SI Motion drive-integrated status signals
Only for SS1 with encoder:
● p9348 SI Motion SBR actual velocity tolerance (Motor Module)
● p9548 SI Motion SBR actual velocity tolerance (Control Unit)
● p9356 SI Motion pulse cancelation delay time (Motor Module)
● p9556 SI Motion pulse cancelation delay time (Control Unit)
Only for SS1 without encoder:
● p9381 SI Motion braking ramp reference value (Motor Module)
● p9581 SI Motion braking ramp reference value (Control Unit)
● p9382 SI Motion brake ramp delay time (Motor Module)
● p9582 SI Motion brake ramp delay time (Control Unit)
● p9383 SI Motion brake ramp monitoring time (Motor Module)
● p9583 SI Motion brake ramp monitoring time (Control Unit)