Safety Integrated Extended Functions
6.2 Safety licenses for 1 to 5 axes
Licenses
The required licenses can optionally be ordered with the converter cabinet.
Retroactive licensing is executed on the Internet via the "WEB License Manager" by
generating a license key:
http://www.siemens.com/automation/license
Note
The process for generating a license key is described in detail in the SINAMICS S120
Function Manual, chapter, "Fundamentals of the drive system" under, "Licensing.
Activation
The associated license key is entered in parameter p9920 in ASCII code. The license key is
activated using parameter p9921 = 1.
Diagnosis
An insufficient license is indicated via the following alarm and LED:
● Warning A13000 → License not sufficient
● LED READY → Flashes green/red at 0.5 Hz