4. Test of the SI function "Safe Stop 2" (SS2)
5. Test of the SI function "Safe Operating Stop" (SOS)
6. Test of the SI function "Safely Limited Speed" (SLS)
7. Test of the SI function "Safe Speed Monitor" (SSM)
C) Functional testing of forced dormant error detection
Test of the forced dormant error detection of the safety functions on each drive (for each
control mode) and the TM54F (if used).
1. Test of the forced dormant error detection of the safety function on the drive
2. Test of the forced dormant error detection of the TM54F (if present)
D) Functional testing of actual value acquisition
Safety Integrated
Function Manual, 05/2010, A5E03264275A
– Only required when used in Extended Functions
– This test is also required if you are not explicitly using SS2 but just one function for
which STOP C occurs as a fault reaction.
Alternatively, you can also carry out the quality test using STOP C yourself, if you use
the table from section "Acceptance test for Safe Stop 2 (Extended Functions)".
– Trace recording is required
– Only required when used in Extended Functions
– This test is also required if you are not explicitly using SOS, but just one function for
which STOP C or STOP D occurs as a fault reaction.
Alternatively, you can also perform the quality test using STOP C and STOP D
yourself, if you use the table from section "Acceptance test for Safe Operating Stop
(Extended Functions)".
– Trace recording is required
– Only required when used in Extended Functions
– A trace recording is required for each SLS limit
– Only required when used in Extended Functions
– Trace recording is required
– If you are using Basic Functions, you need to activate and then deactivate STO once
again.
– If you are using Extended Functions, you need to carry out a test stop.
– Only if Extended Functions are used
– Carry out test stop of the TM54F