If an Alarm Occurs During Another Alarm

Alarms are assigned priority for situations in which multiple alarms occur at the same time.
The following table lists the priority of each alarm. See page 183 for more information on the
operations performed when multiple alarms occur at the same time.
List of Alarms and Calls
Alarms/calls for models
VGDT18143W・VGDT18543W
VGDT18643W・VGDT18145W
Priority
VGDT18645W・VGDT18743W
VGDT18243W・VGDT18343W
VGDT18723W・VGDT18223W
VGDT18323W
Condominium unit at which fire occurred
Fire detector activated alarm
1
*1
Condominium unit at which fire occurred
Fire alarm
Gas leak alarm
If fire occurs on the same floor
2
If fire occurs on the floor directly below
Neighborhood fire alarm
Earthquake alarm (S-wave sensor detection)
3
4
Earthquake alarm (intensity 5-lower or above)
Imperfect combustion (CO) alarm
Emergency alarm
5
Security alarm
*1
Emergency call alarm
General use alarm
Earthquake alarm (intensity of 3 to 4)
6
*1
Earthquake alarm (test report)
Fire detector fault alarm
*1
7
Gas detector fault alarm
Water leak alarm
8
Security preliminary alarm
9
Security lock-up
Earthquake alarm (error)
Elevator stopped
10
*1
Elevator restoredfire confirmation alarm
Call
11
*1
Over-current alarm
12
Delivery notification
*1: Subsequent alarms have higher priority.
*2: Detailed earthquake intensity display only
182
Alarms/calls for models
VGDB18143W, VGDB18543W
VGDB18643W・VGDB18145W
VGDB18645W
—————
Fire alarm
Gas leak alarm
—————
Earthquake alarm (S-wave sensor detection)
*2
*2
Earthquake alarm (intensity 5-lower or above)
Imperfect combustion (CO) alarm
Emergency alarm
Security alarm
Emergency call alarm
General use alarm
Earthquake alarm (intensity of 3 to 4)
Earthquake alarm (test report)
Fire detector fault alarm
Gas detector fault alarm
Water leak alarm
Security preliminary alarm
Security lock-up
Earthquake alarm (error)
Elevator stopped
Elevator restoredfire confirmation alarm
Call
Over-current alarm
Delivery notification
Screen Displays When an Alarm Occurs during Another Alarm
If an alarm is triggered during another alarm, the sub-screen appears displaying the alarm with
higher priority in the center. The message for the alarm with higher priority is played.
If the alarm that occurred afterwards has a lower priority, the alarm display and alarm message
do not change. The screen for this alarm appears in the sub-screen.
Example) If a gas leak alarm (higher priority) occurs during an emergency alarm (lower priority):
Emergency alarm
Screen changes to the gas leak alarm.
Gas leak alarm
● For base unit
To display the screen for an alarm with a lower priority
1
Press the STOP ALARM button
2
Touch
If an alarm with higher priority is reset
The system will change to the alarm display and message for the alarm with the lower priority.
Note
does not appear in the call
sub-base unit with monitor.
● For call sub-base unit with monitor
183