Expire Date of the Gas Alarm

An expiration date is defined to maintain the function of the gas alarm connected to the base unit.
Make sure to replace with a new gas alarm before the expiration date.
Always perform the operation check after replacement.
The gas alarm must conform to the city gas alarm voltage output uniform standard by the Gas Alarm
Industries Association of Japan.
Voltage contact 2-stage output type
(Normal condition: DC6 V, During gas leak alarm: DC12 V, During equipment or wiring abnormality: 0 V)
Voltage contact 3-stage output type (with imperfect combustion (CO) alarm)
Normal condition: DC6 V, During gas leak alarm: DC12 V,
During incomplete combustion: DC18 V, During equipment or wiring abnormality: 0 V
220

Troubleshooting

Stop the alarm sound with the STOP ALARM button when the alarm of the base unit or the call sub-base
Note
unit with monitor does not stop.
Perform following measure if the alarm still does not stop.
● For VGDT item number base unit
As a primary measure for the abnormal condition
of the base unit or the call sub-base unit with
monitor, such as the alarm sound does not stop
with the STOP ALARM button, press the abnormal
case "off" switch, and then contact the
administrating company or the company that
installed the system. (All the function are stopped.)
The abnormal case "off" switch is
under the setting cover.
電源
POWER
Abnormal
case "off"
switch
A
Press the button by piercing the
A
section (section covered with a seal)
using a flathead screwdriver or similar
Only for the base unit for the condominium building (VGDT item number)
There are cases that the function may not stop even the abnormal case "off" switch is pressed.
In such case, remove the base unit cover and disconnect the connectors connected to the base.
Note
There is a danger of exposed power supply when the cover is removed. Do not remove the cover except
when there is an abnormality.
How to remove
1
Remove the cover fixing screw (1 location)
2
Disconnect connectors (2 locations)
Connector
How to install
1 Insert the connectors (2 locations) into
Connector
port
the connector ports on the base
2 Hook the tab at the top of the cover to
the base
3 Fix with the cover fixing screw (1 location)
Base
非常
EMERG.
復旧/警報音停止
RESET/ STOP ALARM
■ Removing the setting cover
火災
確認
FIRE CONFIRM
Open by hooking the finger to
メニュー
the groove
MENU
終了
火災
確認
OFF
FIRE CONF
IRM
メニュ ー
解錠
MEN U
UNLOCK
施工店様へ
■設定時、 この保護シー トを
電源
終了
 はずして設定してください。
POWE R
■設定完了後、 保護シー トを
 もとに戻してください。
通話
OFF
TALK
解錠
UNLO CK
通話
TALK
Groove
Setting cover
The illustration indicates
the VGDT item number
(AC100 V type).
非常
EME RG.
Cover
報音 停止
復旧 /警
M
STOP ALAR
RES ET/
火災
確認
IRM
FIRE CONF
メニュ ー
MEN U
終了
OFF
解錠
電源
UNLO CK
POWE R
施工店
様へ
護シー トを
時、 この保
い。
■設定
定して くださ
通話
 はず して設
、 保護シ
ートを
完了後
てくだ さい。
TALK
 もと に戻し
■設定
Connector
Cover fixing screw
221

Advertisement

Table of Contents
loading

Table of Contents