When Electricity is Overused

The system reports that electricity is being overused when such scenarios occur.
● 
This screen appears when using a distribution panel with over-currency alarm.
Note
● 
Confirm that system components are properly installed before using the system.
The LCD icon will turn off after approximately
1 minute, and the area around the MENU button
will flash in red.
Note
The screen display does not turn off while
electricity usage is 110% or higher.
The on-screen icon can also be turned off
within 1 minute. (
Page 155)
The alarm message stops once electricity usage
is below 100% or below 90%.
How to stop the alarm message
Press the STOP ALARM button.
The alarm message will stop for a moment but
Note
will then continue to sound until the power
consumption is less than either below 100% or
below 90%.
Procedures for message displays
Reduce your power consumption.
The distribution panel settings must
Installer
Setting
be changed to change the
contracted electricity demand.
Consult with the management
company or the company that
installed the system.
174
(Beeps) Too much electricity
is being used.
STOP ALARM button
復旧/警報音停止
RESET/ STOP ALARM
Electricity usage
indicator flashes
in white
MENU button
電源
POWER
Message display
appears in white
Call sub-base unit
ALARM indicator
flashes in red
Display on the base unit when
Alarm is sounding
using a residence distribution
board with over-currency
alarm (data output type)
does not appear in the call sub-base
Note
unit with monitor.
The following message appears in the
display when using a distribution panel
without a level meter.
Message display
appears in red
See page 175 for more information on
LCD displays and alarm messages.
LCD Displays and Alarm Messages
Distribution panels have "limiter ON/OFF" settings. The data output type of distribution panel has "5-stage
Note
display type", and the photocoupler type of distribution panel has "no level display type". The level of electricity
measured by the distribution panel varies depending on the settings and type of distribution panel. Check
which type of distribution panel you have and refer to its operation manual.
■ Using a data output distribution panel with a 5-level display
Power Consumption
Screen display
"Limiter ON"
"Limiter Off"
Message
setting
setting
display
100%-110%
90%-110%
Too much
110%-120%
110%-120%
electricity is
being used.
120% and over
120% and over
■ Using a photocoupler output distribution panel without a level meter
Power consumption
Screen display
"Limiter ON"
"Limiter Off"
Message
setting
setting
display
100%-110%
90%-110%
Too much
110%-120%
110%-120%
electricity is
being used.
120% and over
120% and over

When General Use Alarms Are Triggered

When the general use alarm is triggered, the system reports this event with an alarm display.
Note
Confirm that system components are properly installed before using the system.
The Alarm 1 icon will turn off after approximately
3 minutes, and the area around the MENU button
will flash in red.
The alarm stops once reset. Also, the area around the
MENU button, the call sub-base unit alarm indicator,
and door phone alarm display indicator turn off.
The on-screen icon can also be turned off within
Note
3 minutes. (
Page 155)
Up to 4 general use alarms can be connected.
The screen display appears in accordance with
the configured installation settings.
How to stop the alarm sound
Press the STOP ALARM button.
(The alarm can also be turned off from the building
manager room.)
Alarm
Alarm interval
message
Electricity
usage indicator
Once every 3 minutes
3 flashing green
(Beeps) Too
icons, 1 flashing
much electricity
Once every 10 seconds
yellow icon, and
is being used.
1 flashing
Once every 5 seconds
orange icon
Alarm
Alarm interval
Electricity
message
usage indicator
Once every 3 minutes
(Beeps) Too
much electricity
-
Once every 10 seconds
is being used.
Once every 5 seconds
(Siren)
STOP ALARM button
復旧/警報音停止
RESET/ STOP ALARM
Alarm 1 icon flashes
in red
MENU button
電源
POWER
Call sub-base unit
Door phone
ALARM indicator
Alarm display indicator
Flashes in red
Flashes in red
● For base unit
Alarm is sounding
Alarm is sounding
Note
does not appear in the call sub-base
unit with monitor.
175