In the Event of Imperfect Combustion
When the imperfect combustion state (carbon monoxide) is detected by the gas/CO detector,
the system reports a fault.
Note
This function is only available when using gas detectors with CO alarm functionality.
The ventilation icon will turn off after
approximately 3 minutes, and the area around
the MENU button will flash in red.
Once the imperfect combustion state is no
longer detected, the alarm stops. Also, the
area around the MENU button, ALARM
indicator on the call sub-base unit alarm
indicator, and door phone alarm display
indicator turn off.
The area around the MENU button, ALARM
Note
indicator, and alarm display indicator continue
to flash until the imperfect combustion state
(carbon monoxide) is no longer detected by the
gas/CO detector.
The ventilation icon can also be turned off
within 3 minutes. (
Page 155)
How to stop the alarm sound
Press the STOP ALARM button. Note that the
gas/CO alarm will not turn off. (The alarm can
also be turned off from the building manager
room.)
Procedures during alarms
Open the windows and doors to ventilate the
room.
Stop using the devices causing the incomplete
combustion state.
If the alarm does not stop, contact the store
where purchased or your nearest gas store.
162
(Beeps) The air is
contaminated. Open a window
and ventilate the room.
STOP ALARM
button
復旧/警報音停止
RESET/ STOP ALARM
Ventilation icon
flashes in red
MENU button
電源
POWER
Call sub-base unit
Door phone
ALARM indicator
Alarm display indicator
Flashes in red
Flashes in red
● For base unit
Alarm is sounding
Alarm is sounding
Note
does not appear in the call
sub-base unit with monitor.
In the Event of a Gas Leak or Disconnection
In the Event of a Gas Detector Fault
When the gas detector is disconnected or removed, the system reports a fault.
The gas detector fault icon will turn off after
approximately 1 minute, and the area around
the MENU button will flash in red.
If the gas detector is reconnected or the
removed gas detector is reinstalled, the alarm
stops, and the area around the MENU button,
GAS indicator, and door phone alarm display
indicator turn off.
After pressing the STOP ALARM button,
touching
on the base unit will cause
the screen to return to the waiting state, and
the area around the MENU button will light up
in red. To display the gas detector fault icon,
touch
on the Top Menu screen.
(
Pages 20 to 21)
The GAS indicator appears only on the base unit.
Note
The GAS indicator continues to appear, the area
around the MENU button continues to appear or
flash, and the alarm display indicator continues
to flash until the detector or detector wiring is
reconnected.
The gas detector fault icon can also be turned off
within 1 minute. (
Page 155)
How to stop the alarm sound
Press the STOP ALARM button.
(The alarm can also be turned off from
the building manager room.)
Procedures during alarms
If the gas detector is not experiencing a fault
such as the device being removed or a breaker
being tripped, contact your apartment manager
or system installer.
The alarm can be disabled.
Installer
Setting
Consult with the management
company or the company that
installed the system.
(Beeps)
STOP ALARM
button
復旧/警報音停止
RESET/ STOP ALARM
Gas detector fault
icon appears
in red
MENU button
Confirm button
電源
ガス
GAS
GAS
POWER
indicator
appears
Call sub-base unit
Door phone
in yellow
Alarm is sounding
Alarm display indicator
Flashes in red
Alarm is sounding
● For base unit
and
do not appear in the call
Note
sub-base unit with monitor.
163