Data Transfer: System Memory Into R Parameter - Siemens SINUMERIK 880 Programming Manual

Hide thumbs Also See for SINUMERIK 880:
Table of Contents

Advertisement

01.93
11.6

Data transfer: System memory into R parameter

The main group 3 is organized as follows:
@ 3
x
y
Three-digit @ code
Special function
0: Machine data
1: Setting data
2: Tool offsets
3: Zero offsets
4: Programmed setpoint values
5: External setpoint values (available soon)
6: Actual values
7: Program data
3: Main group 3
All @ commands in main group 3 have <Var> as first notation. This defines directly or via a
pointer an R parameter in which the contents of the addressed system cell are to be loaded.
Main group 3/subgroup 0: Transfer machine data in R parameter
@300 <Var> <Value 1>
The address of an NC machine data is defined in <Value 1>.
Address area: 0 to 4999.
Example:
@300
R50
K2240
@301 <Var> <Value 1>
The byte address of an NC machine data is defined in <Value 1>.
Address area: 5000 to 18240.
@302 <Var> <Value 1> <Value 2>
The byte address of an NC machine data bit is defined in <Value 1>.
Address area: 5000 to 18240. The bit address (0 to 7) is given in <Value 2>.
@303 <Var> <Value 1> <Value 2>
The cycle machine data values are read into parameter<Var>.
Where:
<Value 1>
Channel No.
0: own channel
<Value 2>
Word address
© Siemens AG 1991 All Rights Reserved
SINUMERIK 880, (PG)
11.6 Data transfer: System memory into R parameter
The value of the first software limit switch is given in
parameter R50, in the plus direction for the first axis.
6ZB5 410-0HD02
11 Programming of Cycles
11–13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw 6Sinumerik 880 ga2Sw 1

Table of Contents