Performance Test - Suzuki RA410 Manual

Table of Contents

Advertisement

1B-26 AIR CONDITIONING (OPTIONAL)
1. Thermometer
2
kPa
kg/cm
2000
20
1900
19
1800
18
"A"
1700
17
1600
16
1500
15
1400
14
1300
13
1200
12
1100
11
1000
10
900
9
800
8
700
7
600
6
500
5
"A"
400
4
300
3
200
2
100
1
0
15
20
59
68
Ambient Temperature

PERFORMANCE TEST

1) Confirm that vehicle and environmental conditions are as fol-
2) Connect high and low side charging hoses of manifold gauge
3) Warm up engine to normal operating temperature and keep it
4) Turn A/C switch ON, and set blower switch at "HI", temperature
1
5) Keep all windows, doors and engine food open.
6) With about 20 mm (0.8 in) of dry bulb thermometer inserted into
7) Check for each pressure of low side and high side if it is within
"B"
25
30
35 C
77
86
95 F
lows.
– Vehicle is not exposed to direct sun.
– Ambient temperature is within 15 C – 35 C (59 F – 95 F)
to hose fittings of A/C component.
at specified idle speed. (Radiator cooling fan should not be
working when checking pressure and temperature.)
lever at "COOL", fresh/circulation control lever at "CIRCULA-
TION", (Confirm that A/C compressor and condenser fan are
working.)
center duct air outlet and another one set near evaporator air
inlet, read temperature indicated on each thermometer.
shaded range of left graph.
NOTE:
Pressure registered on gauge varies with ambient temper-
ature. Therefore, use left graphs when determining if pres-
sures are normal or not.
Example:
Gauges should read as follows when ambient temperature
is 30 C
Pressure on high pressure
gauge (HI):
Pressure on low pressure
gauge (LO):
If each gauge reading is out of specified pressure, correct de-
fective part referring to following Diagnosis table.
1400 – 1750 kPa
2
14.0 – 17.5 kg/cm
230 – 350 kPa
2
2.3 – 3.5 kg/cm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents