1B-12 AIR CONDITIONING (OPTIONAL)

RECOVERY, EVACUATION AND CHARGING

OPERATION PROCEDURE FOR CHARGING A/C WITH REFRIGERANT
2
B
A: High pressure service valve
B: Low pressure service valve
1. Manifold gauge set
2. Low pressure gauge
3. High pressure gauge
4. Recovery equipment

REFRIGERANT RECOVERY

When discharging refrigerant out of A/C system, always recover it
1
by using refrigerant recovery and recycling equipment.
3
Discharging it into atmosphere would cause adverse effect to envi-
ronments.
NOTE:
When handling recovery and recycling equipment, be sure to
4
follow the instruction manual for the equipment.

EVACUATING AND CHARGING

Refer to AIR CONDITIONING BASIC MANUAL
(99520-02130).
A
NOTE:
Specified amount of refrigerant: 530
Recharge 530
30 g of
refrigerant in gas form
30g