6H-6 CHARGING SYSTEM
2
3
(a)
WITH CHARGING EQUIPMENT

REMOVAL

1) Disconnect negative cable (1).
2) Disconnect positive cable (2).
3) Remove retainer (3).
4) Remove battery (4).

HANDLING

When handling battery, the following safety precautions should be
followed:
1
4

INSTALLATION

1) Reverse removal procedure.
2) Torque battery cables to specification.
CAUTION:
When jump starting engine with charging equipment, be
sure equipment used is 12-volt and negative ground. Do
not use 24-volt charging equipment. Using such equip-
ment can cause serious damage to electrical system or
electronic parts.
Hydrogen gas is produced by battery. A flame or spark near bat-
tery may cause the gas to ignite.
Battery fluid is highly acidic. Avoid spilling on clothing or other
fabric. Any spilled electrolyte should be flushed with large quan-
tity of water and cleaned immediately.
NOTE:
Check to be sure that ground cable has enough clear-
ance to hood panel by terminal.
Body and battery cable should not interfere with each
other.
After tightening positive terminal, be sure to put cap
onto it securely.
Tightening Torque
.
(a): 8.0 N
m (0.8 kg-m, 6.0 lb-ft)