6H-20 CHARGING SYSTEM
(c)
(b)
Rated voltage
Nominal output
Permissible max. speed
No-load speed
Setting voltage

INSTALLATION

Reverse removal procedure giving specified tension to drive belt
referring to SECTION 6B.
(a)
Tightening Torque
(a): 22 N · m (2.2 kg-m, 16.0 lb-ft)
(b): 50 N · m (5.0 kg-m, 36.5 lb-ft)
(c): 7 N · m (0.7 kg-m, 5.0 lb-ft)

SPECIFICATIONS

12 V
65 A (at 13.5 V)
18,000 rpm
1,180 rpm
14.2 to 14.8 V
Permissible ambient
temperature
Polarity
Rotation
Rotation
– 30 to 90 °C
(– 22 to 194 °F)
Negative ground
Clockwise viewed
from pulley side