1A-8 HEATER AND VENTILATION
a
d
3
b
4
1
1. Heater unit
2. Air inlet box
3. Mode control cable
4. Temperature control cable
5. Fresh air control cable
c
e
f
2
1
3
2
INSTALLATION
1) Reverse removal procedure for installation.
2) Adjust the following items.
i) Move mode control lever (a), temperature control lever (b)
and fresh air control lever (c) fully in arrow direction as shown
in figure.
ii) Push mode lever (d), temperature lever (e) and door link (f)
fully in arrow direction and fix cable with clamp in position as
shown in figure.
NOTE :
After installing control cables, be sure that control levers
move smoothly and stop at proper position.
3) Enable air bag system, if equipped with air bag. Refer to "ENAB-
LING AIR BAG SYSTEM" in section 10B.

BLOWER FAN SWITCH

REMOVAL
1) Disconnect negative (–) cable at battery.
2) Remove meter cluster hood, ashtray, center garnish and radio
or accessory case (if equipped).
3) Remove heater control panel (1) as shown.
Disconnect blower fan switch coupler. Loosen blower fan switch
screw (2) and them remove blower fan switch (3) as follows.
INSTALLATION
Reverse removal sequence to install blower fan switch.