18
PROFIsafe
Table 3: Legend for the iPar Server Figure
No. Explanation
1
Instantiation of the iPar Server function
2
CPD Tool Start and parameter transfer (e.g., node address)
3
Parameterization of individual module parameters (iPar) and
commissioning
4
Transfer of iPar signature (CRC via the individual parameters) to the F-Host
5
During start-up, transfer of the signature to F-slave (Prm_Telegram)
6
Message to iPar server about diagnostic agent (alarm/status)
7
iPar server polls Diag FB and starts "Save" if required
8
iPar server polls Diag FB and starts "Restore" if required
Use the application notes from WAGO!
An overview for using the F I/O module in combination with a safe PLC is
summarized in an application note. This application note is available on the
Internet at www.wago.com under "Service > Downloads > Application Notes ...".