GP 2.3 Keys Pad & LED Layout
Figure 1 illustrates the layout of the Control Panel
Figure 1 Keys Pad and LED Layout
General Procedures / Information
GP 2.3 , GP 2.4

GP 2.4 IOT Diagnostics

The IOT diagnostics provide the ability to:
Print IOT test page.
Read or Set IOT NVM configuration values. Access to NVM is password protected.
Monitor and verify operation of all input sensors for IOT and options.
Monitor and verify operation of all Output devices for IOT and options (motors, clutches,
etc.)
Table 1 summarizes the operation of the Control Panel Keys for entering IOT diagnostics.
Table 1 Entering IOT Diagnostics
Key Combination
-
Item Up + Item Down
Enter
The IOT diagnostic menu has the following selections:
Test Print
NVM Config
Component Test
Table 2 summarizes the operation of the Control Panel keys in IOT diagnostic main menu.
Table 2 IOT Diagnostic Mode Key Table
Key Combination
-
Menu Up / Menu Down
On-line
(Press and hold for 1 second)
02/2000
6-16
Key Number Action
2 + 6
While turning on power press and hold until
message "*IOT*" is displayed on the LCD (it
takes approximately 30 seconds).
During this time the following occurs:
Switch printer power on
Squares (light)
Boot Code Version
IOT displayed
4
After *IOT* is displayed the ENTER key must
be pressed within 5 sec. to enter Diagnostics.
If the ENTER key is not pressed within 5 sec.,
printer will continue its normal power up
sequence.
Key Number Action
1 or 5
Scroll through the IOT diagnostic menu: Print
Menu, NVM Menu, Component Menu.
0
Stops routing in process and clears error mes-
sages from Control Panel.