Operation During Dead Time Timer Mode - Fujitsu MB91260B Series Hardware Manual

32-bit microcontroller
Table of Contents

Advertisement

11.6.4.2

Operation During Dead Time Timer Mode

The dead-time generator inputs real-time output (RT1, RT3, and RT5) or PPG0 timer
pulse output and outputs a non-overlapping signal (reverse signal) to the external pins
(RTO0 to RTO5).
■ Operation During Dead Time Timer Mode
This non-overlapping signal is generated via normal-polarity RT1, RT3, and RT5 (16-bit dead timer
control register (DTCR0, DTCR1, and DTCR2) TMD8 to TMD0 (higher-order bits are 10 to 8; lower-
order bits are 2 to 0) = 100
When the DTCR0, DTCR1, and DTCR2 register DMOD2 to DMOD0 selects the non-overlapping signal
with a value of 0 (normal polarity), a delay equivalent to the non-overlap time set in the 16-bit dead timer
register (TMRRH0 to TMRRH2, TMRRL0 to TMRRL2) is applied. This delay is applied to the rising edge
or falling edge of the RT1, RT3, and RT5 pins. If the RT1, RT3, and RT5 pulse width is less than the
specified non-overlap time, the 16-bit dead timer starts counting down again from the next RT edge
TMRRH0 to TMRRH2, TMRRL0 to TMRRL2 register value.
Figure 11.6-24 Non-overlap Signal Generated by RT1, RT3, and RT5 of Normal Polarity
<Register setting>
TCDTH, TCDTL
TCCSH, TCCSL
CPCLRH, CPCLRL
TMRRH0 to TMRRH2, TMRRL0 to TMRRL2 : XXXX
SIGCR1
Note: Be sure to set according to "X" operation.
16-bit dead timer 0
Count value
TMRR0 set
value
RT1
RTO0(U)
RTO1(X)
).
B
: XXXX
H
: X--XXXXX X0X0XXXX
: XXXX
(Setting of cycle)
H
(Setting of non-overlap timing)
H
: XXXXXXXX
(Setting of DTTI input and 16-bit dead timer count clock)
B
2 machine cycle
Pin name
RTO0 (U)
Delayed signal is applied at rising edge of RT1.
RTO2 (V)
Delayed signal is applied at rising edge of RT3.
RTO4 (W)
Delayed signal is applied at rising edge of RT5.
RTO1 (X)
Delayed inverted signal is applied at falling edge of RT1.
RTO3 (Y)
Delayed inverted signal is applied at falling edge of RT3.
RTO5 (Z)
Delayed inverted signal is applied at falling edge of RT5.
CHAPTER 11 MULTIFUNCTIONAL TIMER
OCCPH, OCCPL0 to 5
: XXXX
OCSH, OCSL0 to 5
: -XX1XXXX XXXXXX11
B
DTCR0 to DTCR2
: 0XXXX100
Output signal
(Compare value)
H
B
B
Time
2 machine cycle
285

Advertisement