• If the cleaning cartridge is not valid, the cleaning
solution will not be automatically filled to the cap.
Open the front cover and use a dropper to fill the
maintenance cleaning solution in the cap to just
before it overflows.
Once the cleaning solution is full, begin from Step
9.
If a message is displayed, open the front
9
cover and check the amount of cleaning
solution in the cap.
• If the solution does not fill up the cap, use a
dropper to fill the maintenance cleaning solution in
the cap to just before it overflows.
Close the front cover, and press the
10
key.
Press
to set the time for the
11
maintenance washing liquid to be left as it
is, and press the
• Set value : 1 to 99 minutes (Unit: minute)
• The maintenance washing liquid filled in the cap is
absorbed.
• "Please Wait" will be displayed in the display until
the time you set has elapsed.
• When nozzle missing is not cleared even after
nozzle recovery (
carried out several times, contact the distributor in
your region or our service office.
key.
P.4-17) or this washing is

Washing the Ink Discharge Passage

Wash the ink discharge passage regularly(about once a
week) to prevent the head nozzles from clogging due to
ink coagulation inside the passage.
• Before washing the ink discharge passage, make
sure that the maintenance washing liquid is set. If
the maintenance washing liquid is not set, washing
operation will not be conducted and the passage
could be clogged.
Press
(MENU)
1
in LOCAL.
• MAINTENANCE MENU will be displayed.
Press the
2
• "STATION" will be selected.
Press
to select "DISWAY
3
WASH", and press the
Press
to select the washing
4
head, and press the
Fill up the cap with cleaning solution for
5
maintenance.
• If the cleaning solution cartridge is usable,
maintenance solution is automatically filled.
• If the front cover is not closed, the cleaning
solution will not be automatically filled. If the front
cover is open, be sure to close it.
• If the cleaning cartridge is not valid, the cleaning
solution will not be automatically filled to the cap.
Open the front cover and use a dropper to fill the
maintenance cleaning solution in the cap to just
before it overflows.
Once the cleaning solution is full, begin from Step 7.
If a END message is displayed, open the
6
front cover and check the amount of
cleaning solution in the cap.
Chapter 4 Maintenance
key.
key.
key.
4-13
1
2
2
4
5
6

Hide quick links: