Load/Motor - Danfoss VLT Refrigeration Drive FC 103 Programming Manual

Hide thumbs Also See for VLT Refrigeration Drive FC 103:
Table of Contents

Advertisement

Parameter Lists
Param-
Parameter description
eter #
0-79
Clock Fault
0-81
Working Days
0-82
Additional Working Days
0-83
Additional Non-Working Days
0-89
Date and Time Readout
4
4

4.1.3 1-** Load/Motor

Param-
Parameter description
eter #
1-0* General Settings
1-00
Configuration Mode
1-03
Torque Characteristics
1-06
Clockwise Direction
1-1* Motor Selection
1-10
Motor Construction
1-1* VVC+ PM/SYN RM
1-14
Damping Gain
1-15
Low Speed Filter Time Const.
1-16
High Speed Filter Time Const.
1-17
Voltage filter time const.
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-28
Motor Rotation Check
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-37
d-axis Inductance (Ld)
1-38
q-axis Inductance (Lq)
1-39
Motor Poles
1-40
Back EMF at 1000 RPM
1-41
Motor Angle Offset
1-44
d-axis Inductance Sat. (LdSat)
1-45
q-axis Inductance Sat. (LqSat)
1-46
Position Detection Gain
1-47
Torque Calibration
1-48
Inductance Sat. Point
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
Min Speed Normal Magnetising
1-51
[RPM]
1-52
Min Speed Normal Magnetising [Hz]
1-58
Flying Start Test Pulses Current
198
®
VLT
Refrigeration Drive FC 103
Default value
4 set-up
[0] Disabled
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
0 N/A
All set-ups
Default value
4 set-up
ExpressionLimit
All set-ups
[0] Compressor CT
All set-ups
[0] Normal
All set-ups
[0] Asynchron
All set-ups
120 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Danfoss A/S © 05/2016 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
Change during
Conversion
operation
index
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
TRUE
-2
TRUE
-2
TRUE
-3
FALSE
1
FALSE
-2
FALSE
0
FALSE
0
FALSE
-2
FALSE
67
FALSE
-1
FALSE
-
FALSE
-
FALSE
-4
FALSE
-4
FALSE
-4
FALSE
-3
FALSE
-6
FALSE
-6
FALSE
0
FALSE
0
FALSE
0
FALSE
-6
FALSE
-6
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
67
TRUE
-1
FALSE
0
Type
Uint8
Uint8
TimeOfDay
TimeOfDay
VisStr[25]
Type
Uint8
Uint8
Uint8
Uint8
Int16
Uint16
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Uint32
Uint16
Uint32
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Int32
Int32
Uint8
Uint16
Int16
Int32
Int32
Uint16
Uint8
Int16
Uint16
Uint16
Uint16
Uint16
MG16H202