Parameter Lists
Param-
Parameter description
eter #
13-9* User Defined Alerts
13-90
Alert Trigger
13-91
Alert Action
13-92
Alert Text
13-9* User Defined Readouts
13-97
Alert Alarm Word
4
4
13-98
Alert Warning Word
13-99
Alert Status Word

4.1.12 14-** Special Functions

Param-
Parameter description
eter #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
14-04
PWM Random
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-16
Kin. Backup Gain
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-42
Minimum AEO Frequency
14-43
Motor Cosphi
14-5* Environment
14-50
RFI Filter
14-51
DC Link Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-59
Actual Number of Inverter Units
14-6* Auto Derate
14-60
Function at Over Temperature
14-61
Function at Inverter Overload
14-62
Inv. Overload Derate Current
206
®
VLT
Refrigeration Drive FC 103
Default value
4 set-up
[0] False
2 set-ups
[0] Info
2 set-ups
ExpressionLimit
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4 set-up
[0] 60 AVM
All set-ups
ExpressionLimit
All set-ups
[1] On
All set-ups
[0] Off
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[0] Trip
All set-ups
100 %
All set-ups
[3] Automatic reset
x 3
All set-ups
60 s
All set-ups
[0] Normal
operation
All set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
[0] No action
All set-ups
0 N/A
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
66 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] On
1 set-up
ExpressionLimit
All set-ups
[0] Auto
All set-ups
[1] Warning
All set-ups
[0] No Filter
1 set-up
ExpressionLimit
1 set-up
[0] Trip
All set-ups
[0] Trip
All set-ups
95 %
All set-ups
Danfoss A/S © 05/2016 All rights reserved.
Change during
Conversion
operation
index
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
0
Change during
Conversion
operation
index
TRUE
-
TRUE
-
FALSE
-
TRUE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-3
FALSE
0
TRUE
0
TRUE
0
TRUE
-2
FALSE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
0
TRUE
-
TRUE
-
TRUE
0
Type
Uint8
Uint8
VisStr[20]
Uint32
Uint32
Uint32
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint32
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
MG16H202