Parameter Description
3.9.5 8-4* Telegram Selection
8-40 Telegram Selection
Option:
3
3
[1]
Standard telegram 1
*
[100] None
[101] PPO 1
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Custom telegram 1
8-42 PCD Write Configuration
Range:
[0]
None
[302]
Minimum Reference
[303]
Maximum Reference
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[412]
Motor Speed Low Limit [Hz]
[413]
Motor Speed High Limit [RPM]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus Control
[615]
Terminal 53 High Ref./Feedb. Value
[625]
Terminal 54 High Ref./Feedb. Value
[653]
Terminal 42 Output Bus Control
[663]
Terminal X30/8 Output Bus Control
[673]
Terminal X45/1 Bus Control
[683]
Terminal X45/3 Bus Control
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[894]
Bus Feedback 1
[895]
Bus Feedback 2
[896]
Bus Feedback 3
[1680]
Fieldbus CTW 1
90
®
VLT
Refrigeration Drive FC 103
Function:
Enables use of freely configurable
telegrams or standard telegrams for
the FC port.
Function:
Danfoss A/S © 05/2016 All rights reserved.
8-42 PCD Write Configuration
Range:
[1682]
Fieldbus REF 1
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[2021]
Setpoint 1
[2022]
Setpoint 2
[2023]
Setpoint 3
[2643]
Terminal X42/7 Bus Control
[2653]
Terminal X42/9 Bus Control
[2663]
Terminal X42/11 Bus Control
8-43 PCD Read Configuration
Range:
[0]
None
[894]
Bus Feedback 1
[895]
Bus Feedback 2
[896]
Bus Feedback 3
[1397]
Alert Alarm Word
[1398]
Alert Warning Word
[1399]
Alert Status Word
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1622]
Torque [%]
[1624]
Calibrated Stator Resistance
[1630]
DC Link Voltage
[1632]
Brake Energy /s
[1633]
Brake Energy /2 min
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1650]
External Reference
[1652]
Feedback[Unit]
[1653]
Digi Pot Reference
[1654]
Feedback 1 [Unit]
[1655]
Feedback 2 [Unit]
[1656]
Feedback 3 [Unit]
Function:
Function:
MG16H202