Danfoss VLT Refrigeration Drive FC 103 Programming Manual page 118

Hide thumbs Also See for VLT Refrigeration Drive FC 103:
Table of Contents

Advertisement

Parameter Description
15-34 Alarm Log: Status
This parameter shows the status of the alarm:
0: Alarm inactive.
1: Alarm active.
3
3
Range:
0
*
15-35 Alarm Log: Alarm Text
Array [10]
Range:
0
*
3.13.5 15-4* Drive Identification
Parameters containing read-only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Shows the FC type. The readout is identical to the frequency
converter series power field of the type code definition,
characters 1–6.
Range:
0
*
15-41 Power Section
Shows the FC type. The readout is identical to the frequency
converter series power field of the type code definition,
characters 7–10.
Range:
0
*
15-42 Voltage
Shows the FC type. The readout is identical to the frequency
converter series power field of the type code definition,
characters 11–12.
Range:
0
*
15-43 Software Version
Range:
0
[0 - 5] View the combined SW version (or package version)
*
consisting of power SW and control SW.
15-44 Ordered Typecode String
Range:
0
[0 - 40] View the type code string used for reordering the
*
15-45 Actual Typecode String
Range:
0
[0 - 40]
*
116
Function:
[0 - 1]
Function:
[0 - 32]
Function:
[0 - 6]
Function:
[0 - 20]
Function:
[0 - 20]
Function:
Function:
frequency converter in its original configuration.
Function:
View the actual type code string.
Danfoss A/S © 05/2016 All rights reserved.
®
VLT
Refrigeration Drive FC 103
15-46 Frequency Converter Ordering No
Range:
0
[0 - 8] View the 8-digit ordering number used for
*
15-47 Power Card Ordering No
Range:
0
[0 - 8]
*
15-48 LCP Id No
Range:
0
*
15-49 SW ID Control Card
Range:
0
[0 - 20]
*
15-50 SW ID Power Card
Range:
0
[0 - 20]
*
15-51 Frequency Converter Serial Number
Range:
0
[0 - 10]
*
15-53 Power Card Serial Number
Range:
0
[0 - 19]
*
3.13.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0, and C1.
15-60 Option Mounted
Array [8]
Range:
0
[0 - 30]
*
15-61 Option SW Version
Array [8]
Range:
0
[0 - 20]
*
15-62 Option Ordering No
Array [8]
Range:
0
[0 - 8] Shows the ordering number for the installed options.
*
Function:
reordering the frequency converter in its original
configuration. To restore the ordering number after
the power card exchange, see
parameter 14-29 Service Code.
Function:
View the power card ordering number.
Function:
[0 - 20]
View the LCP ID number.
Function:
View the control card software version number.
Function:
View the power card software version number.
Function:
View the frequency converter serial number.
Function:
View the power card serial number.
Function:
Shows the type of the installed option.
Function:
View the installed option software version.
Function:
MG16H202