Parameter Description
0-20 Display Line 1.1 Small
Option:
[39]
Display Text 3
3
3
[89]
Date and Time
Readout
[953]
Profibus
Warning Word
[1397] Alert Alarm
Word
[1398] Alert Warning
Word
[1399] Alert Status
Word
[1501] Running Hours
[1502] kWh Counter
[1580] Fan Running
Hours
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual
Value [%]
[1609] Custom Readout View the user-defined readouts as
[1610] Power [kW]
[1611] Power [hp]
[1612] Motor Voltage
[1613] Frequency
28
®
VLT
Refrigeration Drive FC 103
Function:
Enables an individual text string to be
written for display in the LCP, or to be
read via serial communication.
Displays the current date and time.
Displays PROFIBUS communication
warnings.
View the number of running hours of
the motor.
View the mains power consumption in
kWh.
View the control word sent from the
frequency converter via the serial
communication port in hex code.
Total reference (sum of digital/analog/
preset/bus/freeze reference/catch up,
and slow-down) in selected unit.
Total reference (sum of digital/analog/
preset/bus/freeze reference/catch up,
and slow-down) in percent.
Present status word
View the 2-byte word sent with the
status word to the bus master
reporting the main actual value.
defined in:
Parameter 0-30 Custom
Readout Unit.
Parameter 0-31 Custom
Readout Min Value.
Parameter 0-32 Custom
Readout Max Value.
Actual power consumed by the motor
in kW.
Actual power consumed by the motor
in hp.
Voltage supplied to the motor.
Motor frequency, that is the output
frequency from the frequency converter
in Hz.
Danfoss A/S © 05/2016 All rights reserved.
0-20 Display Line 1.1 Small
Option:
Function:
[1614] Motor current
Phase current of the motor measured
as effective value.
[1615] Frequency [%]
Motor frequency, that is the output
frequency from the frequency converter
in percent.
[1616] Torque [Nm]
Present motor load as a percentage of
the rated motor torque.
[1617] Speed [RPM]
Motor speed reference. Actual speed
depends on slip compensation being
used (compensation set in
parameter 1-62 Slip Compensation). If
not used, actual speed is the value
read in the display minus motor slip.
[1618] Motor Thermal
Thermal load on the motor, calculated
by the ETR function. See also parameter
group 1-9* Motor Temperature.
[1622] Torque [%]
Shows the actual torque produced, in
percentage.
[1624] Calibrated Stator
Resistance
[1630] DC Link Voltage
Intermediate circuit voltage in the
frequency converter.
[1631] System Temp.
[1632] Brake Energy /s
Present brake power transferred to an
external brake resistor.
Stated as an instant value.
[1633] Brake Energy /2
Brake power transferred to an external
min
brake resistor. The average power is
calculated continuously for the most
recent 120 s.
[1634] Heatsink Temp.
Present heat sink temperature of the
frequency converter. The cutout limit is
95 ±5 °C (203 ±9 °F); cutting back in
occurs at 70 ± 5 °C (158 ±9 °F).
[1635] Inverter Thermal Percentage load of the inverters.
[1636] Inv. Nom.
Nominal current of the frequency
Current
converter.
[1637] Inv. Max.
Maximum current of the frequency
Current
converter.
[1638] SL Controller
State of the event executed by the
State
control.
[1639] Control Card
Temperature of the control card.
Temp.
[1650] External
Sum of the external reference as a
Reference
percentage, that is the sum of analog/
pulse/bus.
[1652] Feedback[Unit]
Reference value from programmed
digital input(s).
MG16H202