ASCOM Ascotel 2025 System Manual page 381

Isdn telecommunications system
Table of Contents

Advertisement

ascom
Ascotel 2025/2045/2065
Setting LCR to PINX 1:
• The digit sequence "60" is entered in the LCR table.
– All outgoing, PISN-internal calls whose phone number begins with "60" will
be analysed by LCR.
• In the routing table the entry for the first network provider stays blank. How-
ever, an alternative network provider is entered.
• Under normal conditions, calls whose phone number begin with "60" will be
routed in accordance with the subscriber configuration. If the normal path is
not available, the calls will be routed via the alternative network operator.
• The network operator table determines the route via which the alternatively
routed calls are to be routed.
• In the network operator table the PISN phone number must be converted into
an external direct dial number. The master number of PINX 2 is used for this
purpose without its direct dial portion. The direct dial portion is formed by
using the PISN subscriber number without regional prefix.
This means that all the subscribers on PINX 2 need only one entry in the LCR
configuration. This can only be achieved if the DDI numbers match the internal
subscriber numbers.
Tab. 2.68:
Settings for overflow routing on PINX 1
Parameter
LCR table:
• I60 (regional prefix for PINX 2)
Routing table "O-flow PINX 2":
• Time zone x
Network operator table:
• Network provider "PINX 2"
• Conversion rule
Route 6:
• Name
• Trunk groups
• Digit barring
• Outgoing connections
• Numbering plan identifier NPI
2.204
Call Routing
Parameter value
O-flow PINX 2 (allocate to routing table "O-flow PINX 2")
• Service provider: -
• Alternative service provider: PINX 2
• Times: Allocate the times for "PINX 2"
Route 6
0666666<3-.> (master number of PINX 2 without three-digit
direct dial portion and the last three digits of the dialled phone
number. If, for example, SC A dials 60300, the number
0666666300 is used, which corresponds to the direct dial
number of SC B).
PINX 2, subscriber
2
No (do not consult digit barring)
Number of connections allowed simultaneously
E.164
HBT_20321104_02/B0_en

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ascotel 2045Ascotel 2065

Table of Contents