4.1.1
Uninterruptible Power Supply (UPS)
The use of an uninterruptible power supply (UPS) guarantees that the PBX can be
reliably operated even in the event of a failure of the 230 VAC power supply.
Uninterruptible power supply can be provided by the UPS-12V module or an
external UPS.
4.1.1.1
UPS with UPS-12V Module
The charging circuit of the UPS-12V module is designed for lead-acid batteries
with a floating charge voltage of approx. 13.6. The charge current can be limited
to 1 or 2 A. The battery switching circuit is secured on the module with 20 A
(Wickmann FK1 20 A). If the polarity is the wrong way around, the fuse breaks
the circuit and must then be replaced.
Mainboard
[1] Primary connector
[2] Secondary connector
[3] Cable clamp (Faston 6.3 mm)
[4] Rubber grommet
[5] Cable to 12V back-up battery (cable cross-section 4 mm
[6] 12V back-up battery (external)
Fig. 4.13:
Connecting UPS-12V module
HBT_20321104_04/B0_en
ascom
1 6
6
1
[1]
[2]
UPS-12V
2
Ascotel 2025/2045/2065
haz1186aadeb0
+
[4]
[3]
-
)
PBX Power Supply
[5]
[6]
12 V
4.13