Configuration Steps; System Initialization; Hardware-Induced Initialization; Software-Induced Initialization - ASCOM Ascotel 2025 System Manual

Isdn telecommunications system
Table of Contents

Advertisement

5

Configuration Steps

The configuration steps are based on the information determined during the plan-
ning and, where applicable, the installation.
5.1

System Initialization

Before work can begin, the system has to be brought into a defined state. This
involves setting or deleting all the parameter values to their initialization value and
carrying out a self-test.
This initialization can be achieved in the following ways:
• With the HEX rotary switch on the mainboard
• With AIMS
5.1.1

Hardware-induced Initialization

1. Set the HEX rotary switch on the mainboard to "1".
2. Switch the system off and back on again. The system is restarted.
3. When a flashing "1" appears on the display, turn the HEX rotary switch to
"F".
4. When an "F" appears, turn the HEX rotary switch to "0"; the PBX resets the
customer data (Flash EPROM).
5.1.2

Software-induced Initialization

1. Carry out a "System Initialization"; this requires authorization level 3 or 4 (for
initialization use the password "3ascotel" for the Installer or "4ascotel" for
the Service Centre, or turn the HEX rotary switch on the mainboard to posi-
tion "5").
2. After initialization the system is ready for configuration. Once the configura-
tion is completed carry out a functional test (see "Part 6: Commissioning").
HBT_20321104_05/B0_en
ascom
Ascotel 2025/2045/2065
Configuration Steps
5.21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ascotel 2045Ascotel 2065

Table of Contents