gefran AFE200 4 Series Instruction Manual page 79

Active front end regenerative power supply unit
Table of Contents

Advertisement

Menu
PAR
Description
1.17
1066
Enable state mon
The AFE Enable command status is displayed. Voltage must be present on terminal 7.
The FR Forwardstart command is needed to start the AFE200.
0
Disabled
1
Enabled
Menu
PAR
Description
1.18
1100
Digital input mon
The status of the digital inputs on the AFE is displayed. It can also be read via a serial
line or fieldbus. The data are contained in a word, where each bit is 1 if voltage is sup-
plied to the corresponding input terminal.
0
Input disabled
1
Input enabled
I.e. :
Menu
PAR
Description
1.19
1300
Digital output mon
The status of the digital outputs on the AFE is displayed. It can also be read via a se-
rial line or fieldbus. The data are contained in a word, where each bit is 1 if voltage is
supplied to the corresponding input terminal.
0
Output disabled
1
Output enabled
I.e. :
Menu
PAR
Description
1.20
1200
Digital input X mon
The status of the digital inputs of the expansion card is displayed. It can also be read
via a serial line or fieldbus. The data are contained in a word, where each bit is 1 if
voltage is supplied to the corresponding input terminal.
0
Input disabled
1
Input enabled
I.e. :
UM
Type
BIT
AFE disabled
AFE enabled
UM
Type
UINT16
000000000011
000000000011
Active DI 2
Active DI 1
UM
Type
UINT16
000000000011
000000000011
Active DO 2
Active DO 1
UM
Type
UINT16
000000000011
000000000011
Active DI 2
Active DI 1
AFE200 • Instruction Manual
FB BIT
Def
16
0
FB BIT
Def
16
0
FB BIT
Def
0
FB BIT
Def
16
0
Min
Max
Acc
0
1
Min
Max
Acc
0
0
Min
Max
Acc
0
0
Min
Max
Acc
0
0
79
R
R
R
R