gefran AFE200 4 Series Instruction Manual page 166

Active front end regenerative power supply unit
Table of Contents

Advertisement

Error message shown on the
display
Options config error
Option detect slot 1
Option detect slot 2
Option detect slot 3
Plc cfg error
166
Sub-code
002AH-42 PLC application release and version not compatible.
All parameters in the keypad memory have been transferred to the AFE.
The transferred set of parameters relates to a AFE with a PLC application in which the
version and release of the application are different. As a result some of the PLC applica-
tion parameters may not be updated.
002BH-43 PLC application not compatible.
All the parameters in the keypad memory except those relating to the PLC applciation
have been transferred to the AFE.
The transferred set of parameters relates to a AFE with a different PLC application. As a
result none of the PLC application parameters are updated.
Solution: Recover a set of parameters from a compatible AFE (model and size)
Condition: may occur at AFE start-up, during recognition of the optional cards installed
0001H-1
Non-permissible optional card in slot 1
0002H-2
Non-permissible optional card in slot 2
0004H-4
Non-permissible optional card in slot 3
0010H-16 Conflict slot 1 with slot 2
0020H-32 Conflict slot 1 with slot 3
0040H-64 Conflict slot 2 with slot 3
Solution: Remove the optional cards from the incorrect slots and insert them in the correct slots
Condition: at power-on, the AFE recognizes the presence of an optional card in one of the three
expansion slots.
One of the three messages is shown on the display
0H-0
None
0001H-1
I�O�1
0004H-4
Can�Dnet
00FFH-255 Unknown
0101H-257 I�O�2
0104H-260 Profibus
0020H-32
Fast IO (Sync-ON card)
0201H-513 I�O�3
0204H-516 Gdnet
0301H-769 I�O�4
Solution:
Condition: may occur during loading of the Mdplc application
The Mdplc application present on the AFE is not run.
0004H-4
The application downloaded has a different Crc on DataBlock and Function table
0065H-101 The application downloaded has an invalid identifier (Info)
0066H-102 The application downloaded has an incorrect task number (Info)
0067H-103 The application downloaded has an incorrect software configuration
0068H-104 The application downloaded has a different Crc on DataBlock and Function table
0069H-105 A Trap error or System error has occurred.
The AFE automatically performs a Power-up operation.
The application is not run.
See in Alarm List for further information regarding the error occurred
006AH-106 The application downloaded has an incorrect identifier (Task)
006BH-107 The application downloaded has an incorrect task number (Task)
006CH-108 The application downloaded has an incorrect Crc (Tables + Code)
Solution: Remove the Mdplc application or download a correct Mdplc application
AFE200 • Instruction Manual
Description

Advertisement

Table of Contents
loading

Table of Contents