10 - Specification

10.1 Environmental Conditions

Installation location ������������������Pollution degree 2 or lower (free from direct sunligth, vi-
Installation altitude ������������������Max 2000m (6562 feet) above sea level;.
Mechanical conditions for installation ���Vibrational stress: EN 60721-3-3 Class 3M1
Operating temperature ��������������-10...+40°C (32°...104°F)
Operating temperature (1) ������������+40 ... +50°C with derating, (+104 ... +122°F with
Air humidity (operating) ��������������5 % to 85 % and 1 g/m
Air pressure (operating) [kPa] ����������86 to 106 (class 3K3 as per EN50178)
(1)

10.2 Standards

Climatic conditions ������������������EN 60721-3-3
Electrical safety ��������������������EN 50178, EN 61800-5-1, UL508C, UL840 degree of
Vibration ��������������������������EN 60068-2-6, test Fc.
EMC compatibility �������������������EN61800-3
Protection degree �������������������Sizes 3.. 6: IP20;
EC Directives �����������������������LVD 2014/35/EU, EMC 2014/30/EU, RoHs 2011/65/EU
Approvals �������������������������
(*)

10.3 Accuracy

10.3.1 Current control

Loop sampling time ������������������62,5µs
Response time ����������������������800 - 1000µs
PWM frequency ���������������������2, 3, 4, 6, 8 kHz (size dependent)

10.3.2 Voltage control

Loop sampling time �������������������62,5µs
Response time ����������������������10 - 15ms

10.3.3 Current rating

Heavy duty (HD) ���������������������150% 60 sec, 180% 0.5 sec.
Light duty (LD) ����������������������110% 60 sec.
Switching frequency mode (LD) ����������2, 3 or 4 kHz, size dependent
Switching frequency mode (HD) ���������2, 3, 4, 6, 8 kHz
168
In menu 4 - DRIVE CONFIG set the Ambient temperature parameter, PAR 564, to 1 (50°C).
10 % derating of output current.
Sizes AFE200-...-6 with 690 V power supply are not UL-marked..
AFE200 • Instruction Manual
bration, dust, corrosive or inflammable gases, fog, vapour
oil and dripped water, avoid saline environment)
derating)
to 25 g/m
3
condensation or icing (class 3K3 as per EN50178)
pollution 2
Size 7: IP00 (with protection against accidental contact)
(*)
without moisture
3