14.4.37 4270
Fieldbus S->M10 ipa
14.4.41 4280
Fieldbus S->M11 ipa
14.4.45 4290
Fieldbus S->M12 ipa
14.4.49 4300
Fieldbus S->M13 ipa
14.4.53 4310
Fieldbus S->M14 ipa
14.4.57 4320
Fieldbus S->M15 ipa
14.4.61 4330
Fieldbus S->M16 ipa
Setting of the parameter to associate with the bus channel. The default setting is 0,
which means channel not active.
When setting a parameter, the format is also automatically set in the sys parameter
Menu
PAR
Description
14.4.2
4182
Fieldbus S->M1 sys
14.4.6
4192
Fieldbus S->M2 sys
14.4.10 4202
Fieldbus S->M3 sys
14.4.14 4212
Fieldbus S->M4 sys
14.4.18 4222
Fieldbus S->M5 sys
14.4.22 4232
Fieldbus S->M6 sys
14.4.26 4242
Fieldbus S->M7 sys
14.4.30 4252
Fieldbus S->M8 sys
14.4.34 4262
Fieldbus S->M9 sys
14.4.38 4272
Fieldbus S->M10 sys
14.4.42 4282
Fieldbus S->M11 sys
14.4.46 4292
Fieldbus S->M12 sys
14.4.50 4302
Fieldbus S->M13 sys
14.4.54 4312
Fieldbus S->M14 sys
14.4.58 4322
Fieldbus S->M15 sys
14.4.62 4332
Fieldbus S->M16 sys
When setting the sorg parameter the format is automatically set on the relative sys.
If sorg is set to null, the data format does not change. The value of the format can be
selected from the following list, according to the parameter selected as the source:
0
Not assigned
1
Count 16
2
Count 32
3
Fill 16
4
Fill 32
5
Mdplc 16
6
Mdplc 32
7
EU
8
Eu float
9
Par 16
10
Par 32
If set to 0 the channel is not assigned.
If set to 1 the datum is assigned a 16-bit count.
If set to 2 the datum is assigned a 32-bit count.
If set to 3 16 bits on the channel are reserved for the datum, not used.
If set to 4 32 bits on the channel are reserved for the datum, not used.
If set to 5 the datum is assigned a 16-bit count used by MDPLC.
If set to 6 the datum is assigned a 32-bit count used by MDPLC.
If set to 7 the datum is assigned engineering units on a 16-bit integer.
If set to 8 the datum is assigned engineering units on a 32-bit integer.
If set to 9, the datum is assigned a 16-bit integer engineering unit format not in real
time (5-10ms)
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
UM
Type
FB BIT
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
ENUM
AFE200 • Instruction Manual
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Def
Min
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
Not assigned 0
20000
RW
20000
RW
20000
RW
20000
RW
20000
RW
20000
RW
20000
RW
Max
Acc
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
10
RW
131