gefran AFE200 4 Series Instruction Manual page 130

Active front end regenerative power supply unit
Table of Contents

Advertisement

Sys parameter
Count 32
Count 16
monitor. Error
A Fieldbus M->S X Mon parameter can only be assigned to a single "src". If assigned
to more than one src, an error signal is generated during fieldbus initialization.
Menu
PAR
Description
14.3.4
4026
FIeldbus M->S1 div
14.3.8
4036
FIeldbus M->S2 div
14.3.12 4046
FIeldbus M->S3 div
14.3.16 4056
FIeldbus M->S4 div
14.3.20 4066
FIeldbus M->S5 div
14.3.24 4076
FIeldbus M->S6 div
14.3.28 4086
FIeldbus M->S7 div
14.3.32 4096
FIeldbus M->S8 div
14.3.36 4106
FIeldbus M->S9 div
14.3.40 4116
FIeldbus M->S10 div
14.3.44 4126
FIeldbus M->S11 div
14.3.48 4136
FIeldbus M->S12 div
14.3.52 4146
FIeldbus M->S13 div
14.3.56 4156
FIeldbus M->S14 div
14.3.60 4166
FIeldbus M->S15 div
14.3.64 4176
FIeldbus M->S16 div
The Div M->Sx fieldbus parameters can be used to increase the resolution of the
datum sent on the bus to the AFE in the corresponding channel in EU and EU_float
exchange mode. The parameter value is used by the AFE as the divider of the incom-
ing datum, so that a number with decimal digits can be transferred.
Note!
You must check the size in bits of the datum that is sent to make sure that the maximum value in bits
fits in a 16-bit integer. For example, if specifying the divider as "Fieldbus M->Sn div" = 1000, the
maximum value that can be used for the exchanged datum is 32.768 (32768/1000).
I.e. : FIeldbus M->S1 div = 10, Fieldbus S->M1 ipa = Ramp ref src 1, Fieldbus
M->S1 sys = Eu. If the PLC sends the decimal value 1000 on the first word the value
of DC voltage ref src on the AFE is 1000/10 = 100.
14.4 - COMMUNICATION/FIELDBUS S2M
Menu
PAR
Description
14.4.1
4180
Fieldbus S->M1 ipa
14.4.5
4190
Fieldbus S->M2 ipa
14.4.9
4200
Fieldbus S->M3 ipa
14.4.13 4210
Fieldbus S->M4 ipa
14.4.17 4220
Fieldbus S->M5 ipa
14.4.21 4230
Fieldbus S->M6 ipa
14.4.25 4240
Fieldbus S->M7 ipa
14.4.29 4250
Fieldbus S->M8 ipa
14.4.33 4260
Fieldbus S->M9 ipa
130
FB type
result
32 bit
Receives 32 bits from FB and copies to 32 bits of monitor. OK
32_H
Receives 32 bits from FB and copies to 32 bits of monitor. OK
32_L
Receives 32 bits from FB and copies to 32 bits of monitor. OK
16 bit
Receives 16 bits from FB and doesn't know whether to copy to 16H or 16L of
16_H
Receives 16 bits from FB and copies to 16H bit of monitor. OK
16_L
Receives 16 bits from FB and copies to 16L bit of monitor. OK
UM
Type
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
UM
Type
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
FBM2SIPA
AFE200 • Instruction Manual
FB BIT
Def
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
FB BIT
Def
0
0
0
0
0
0
0
0
0
Min
Max
Acc
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
1.0
1000.0 ERW
Min
Max
Acc
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW
0
20000
RW