gefran AFE200 4 Series Instruction Manual page 115

Active front end regenerative power supply unit
Table of Contents

Advertisement

10.31
5468
Dig Analog out 4 ext
10.32
5470
Dig Analog out 5 ext
10.33
5472
Dig Analog out 6 ext
10.34
5474
Dig Analog out 7 ext
These parameters are used with I/O remotable module ( EXP-FL-XCAN-ADV expan-
sion board is needed).
Analog output modules can have a resolution of 12 to 16 bits and scaling may vary
from manufacturer to manufacturer.
E.g.:
12-bit module
Signal connected
Module configuration
16-bit module
Signal connected
Module configuration
There is no single unit that is suitable for all models of analog output module.
Check the scaling provided by the model being used and use the system variables
accordingly.
Analog output 0 and analog output 1 can also be managed by the drive parameters.
To ensure correction operation, the scaling provided by the external module must be
compatible with the scaling provided by the drive.
The drive supplies a datum for the I/O modules scaled as follows
Analog input type
Analog outputs 0..1 are managed via drive parameters and the value produced by the
drive overwrites that written by the MDPLC or serial communication or fieldbus.
Variant 1
-10V..+10V
-2048..+2047
0V..+10V
0..+4095
4..20mA
0..+32767
Variant 1
-10V..+10V
-32768..+32767
0V..+10V
0..+65535
4..20mA
Range
-10V..+10V
-32768..+32767
0V..+10V
0..+65535
4..20mA
+13107..+65535
1866 An out 1X mon
5460 Dig Analog out 0 ext
R
1868 An out 2X mon
R
5462 Dig Analog out 1 ext
R
5464 Dig Analog out 2 ext
W
R
5466 Dig Analog out 3 ext
W
R
5468 Dig Analog out 4 ext
W
R
5470 Dig Analog out 5 ext
W
R
5472 Dig Analog out 6 ext
W
R
5474 Dig Analog out 7 ext
W
AFE200 • Instruction Manual
INT16
16BIT
0
INT16
16BIT
0
INT16
16BIT
0
INT16
16BIT
0
Variant 2
-32768..+32767
0..+2047
+6553..+32767
Variant 2
0..+32767
sysEAO0Value
sysExtIOAnaOut0
sysEAO1Value
sysExtIOAnaOut 1
sysExtIOAnaOut 2
sysExtIOAnaOut 3
sysExtIOAnaOut 4
sysExtIOAnaOut 5
sysExtIOAnaOut 6
sysExtIOAnaOut 7
-32768
32767 ERW
-32768
32767 ERW
-32768
32767 ERW
-32768
32767 ERW
Variant 3
Variant 4
-16384..+16383
0..+16383
0..+32767
+3276..+16383
Variant 3
P
D
O
P
D
O
115