> Calculation of the current required on the DC-link:
P
[
outm
P
=
dc
Vdclink * η
> Choosing the power supply unit:
The AFE200 must be capable of delivering a current of ≥ 220 A
Choose the size with the appropriate characteristics from the section
trical data" on page
AFE200-61320.
> Choosing the drive:
Choose the size with the rated current required by the motor (≥ 236A) from the
catalogue (section ADV200-DC "2.7 Output Data"):
With a 650 Vdc drive:
ADV-71600-...-DC (In = 270A, OK).
Drive
ADV200-DC
AFE + components
AFE Regen unit
Pre-charge kit
LCL KIT
EMI filter
Fuses mains side connection
Checking total DC-link capacity:
AFE200-61320 with ADV-71600-...-4-DC = 13600 + 16800 = 30400 μF ≤ 43000 μF
(OK). See table on page 48.

A1.2 Calculation for multi-motor system

Mains:
v
= three-phase 400Vac
mains
Motor 1: P
= 18.5
outm
v
= 400v
outm
η
= 0.95
m
i
= 37a
m
Application: continuous load, Pcont= 85%
Requested overload = 130%
Motor 2: P
= 18.5
outm
v
= 400v
outm
η
= 0.95
m
i
= 37a
m
Application: continuous load, Pcont = 90%
Requested overload = 130%
Motor 3: P
= 22
outm
v
= 400v
outm
W]
132 * 1000
k
* η
650 * 0.95 * 0.97
m
d
170:
Description
ADV-71600-KXX-4-DC
Description
AFE200-61320-KXX-4
PRE CHARGE KIT-AFE-90/132-4
LCL-Kit-AFE-4-132-HD
EMI FN3120 -480V-230A
S1üf1/110/315A/690V
W
k
ca
W
k
ca
W
k
ca
AFE200 • Instruction Manual
= 220 a
"10.6 Elec-
Code
S9O20DC
Code
S9AF04
S728281
S7LC03
S74EE
F4G30
Q.ty
1
1
1
1
1
3