Setting of the time within which the Undervoltage [2] alarm must be reset in order to
perform automatic restart. (Time with alarm signal active + 100 msec).
Menu
PAR
Description
15.29
4650
UVRep attempts
Setting of the maximum number of attempts at automatic restart after the Undervolt-
age [2] alarm before a Mult Undervoltage [6] alarm is generated. If this parameter
is set to 1000 an infinite number of attempts are available.
Menu
PAR
Description
15.30
4652
UVRep delay
Setting of the time within which, if no automatic restarts are executed after the Und-
ervoltage [2] alarm, the attempts counter is reset. In this way the number of attempts
set in UVRep attempt are still available.
Menu
PAR
Description
15.31
4670
Optionbus activity
Setting of the behaviour of the AFE product in case of an Opt Bus Fault [16] alarm.
0
Ignore
1
Warning
2
Disable
Menu
PAR
Description
15.32
4690
ExtIO activity
This parameter is used to configure the behaviour of the drive if the "Ext I/O fault" [27]
alarm occurs when the EXP-FL-XCAN-ADV card is installed.
See Chapter 9 - "Ext I/O fault" [27] alarm.
When the alarm is activated due to a communication error, the last value that was
received is maintained.
The following activities are programmable:
0
Ignore
1
Warning
2
Disable
You can check whether a card that supports XCAN External IO functions is installed
from the DRIVE INFO menu for parameters 530, 532, 534 SlotX card type:
Value
832
Menu
PAR
Description
15.33
4940
FL fault activity
This parameter is used to configure the behaviour of the drive when the "FastLink
fault" [28] alarm occurs.
If the EXP-FL-XCAN-ADV card is installed in the drive, all the FastLink communica-
tion fault signals are enabled and managed via generation of a "FastLink fault" [28]
alarm, with different subcodes to indicate the cause of the error.
See Chapter 9 - "FastLink Fault" [28] alarm.
UM
Type
UINT16
UM
Type
s
UINT16
UM
Type
ENUM
UM
Type
ENUM
Description
Expansion
IO FastLink
EXP-FL-XCAN-ADV
UM
Type
ENUM
AFE200 • Instruction Manual
FB BIT
Def
5
FB BIT
Def
240
FB BIT
Def
Disable
FB BIT
Def
Disable
XCAN External IO supported
FB BIT
Def
Disable
Min
Max
Acc
0
1000
ERW
Min
Max
Acc
0
300
ERW
Min
Max
Acc
0
2
ERW
Min
Max
Acc
0
2
ERW
Min
Max
Acc
0
2