Scanning Of The Parameters; List Of The Last Parameters Modified; Goto Parameter" Function - gefran AFE200 4 Series Instruction Manual

Active front end regenerative power supply unit
Table of Contents

Advertisement

3
Depends on the type of parameter:
● Numeric parameter: displays the numeric value of the parameter, in the
format required, and unit of measurement (figure A).
● Binary selection: the parameter may assume only 2 states, indicated as
OFF-ON or 0 - 1 (figure B).
● LINK type parameter: displays the description of the parameter set from the
selection list (figure C).
● ENUM type parameter: displays the description of the selection (figure D)
● Command: displays the method of execution of the command (figure E)
4
In this position, the following may be displayed:
● Numeric parameter: displays the default, minimum and maximum values
of the parameter. These values are displayed in sequence pressing the ► key
(figure A).
● LINK type parameter: displays the number (PAR) of the parameter set (fig-
ure C) .
● ENUM type parameter: displays the numeric value corresponding to the cur-
rent selection (figure D).
● Command: in the case of an error in the command, indicates that ESC must
be pressed to terminate the command (figure G).
● Messages and error conditions (figure F):
Param read only
attempt to modify a read-only parameter
Password active
the parameter protection password is active
Drive enabled
attempt to modify a non-modifiable parameter with the AFE enabled
Input value too high the value entered too high
Input value too low the value entered too low
Out of range
attempt to insert a value outside the min. and max. limits

6.2.3 Scanning of the parameters

T+
T -
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG

6.2.4 List of the last parameters modified

Pressing the CUST key, a list containing the last 10 parameters modified is ac-
cessed. One parameter at a time is displayed and the list can be scrolled using
the ▲ and ▼ keys.
To exit this list, press the ► key.

6.2.5 "Goto parameter" function

Pressing the CUST key twice, or once if already in the "List of modified param-
eters", the "Goto parameter" is activated.
This function permits access to any parameter entering only the software number
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 1
PA R :
2 5 0
Out p ut current
0. 3
+
A
AFE200 • Instruction Manual
. . .
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 2 2
PA R :
10 6 0
Se q uencer status
0
T+
T-
EN
LOC
ILim
n:0
AL
0 1 . 0 2
PA R :
2 5 2
Out ut volta e
p
g
1
-
V
. . .
61