How To Save Parameters - gefran AFE200 4 Series Instruction Manual

Active front end regenerative power supply unit
Table of Contents

Advertisement

T+
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 REFERENCE
Pressing E, modification mode is activated. The entire line is displayed in reverse.
The elements of the list of parameters associated to this parameter can be
scrolled using the ▲ and ▼keys.
Press E to confirm the modification or ESC to cancel.
The parameter may assume only the values contained in a selection list.
T+
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
Pressing E, modification mode is activated. The entire line is displayed in reverse.
The elements of the selection list can be scrolled using the ▲ and ▼ keys.
Press E to confirm the modification or ESC to cancel.
A parameter can be used to carry out a number of operations on the AFE.
For an example, see
is displayed instead of the value.
To perform the command, press E.
During execution of the command, the "In progress" caption is displayed to indi-
cate that the operation is in course.
At the end of execution, if the result is positive, the "Done" caption is displayed for
few seconds.
If execution has failed, an error message is displayed.

6.4 How to save parameters

Menu 04 DRIVE CONFIG, parameter 04.01 Save parameters, PAR : 550.
Used to save changes to parameter settings so that they are maintained also at
the power-off.
T+
T -
EN
LOC
ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
To exit, press the ◄ key.
T -
EN
LOC
ILim
n:0
AL
T+
0 5 . 0 5
DC volta g e ref src
Di g DC volta g e ref
Value:
x 5
ENUM type parameter
T -
EN
LOC
ILim
n:0
AL
Execution of commands
paragraph
T+
T-
EN
LOC
ILim
n:0
0 4 . 0 1
PA R :
5 5 0
Save arameters
p
Press E to execute
AFE200 • Instruction Manual
T-
EN
LOC
ILim
n:0
AL
T+
PA R :
6 0 8
0 5 . 0 4
DC volta g e ref src
E
Di g DC volta g e ref
600
Value:
T+
T-
EN
LOC
ILim
n:0
AL
X 2
0 4 . 0 3
PA R :
5 5 4
Access mode
Eas
Y
Value
0
6.4: in this case, the "Press E to execute" request
AL
T+
T-
EN
LOC
0 4 . 0 1
E
Save arameters
p
In ro ress
p
g
T+
T-
0 5 . 0 4
DC volta g e ref src
Test g en out
Value:
T-
EN
LOC
ILim
n:0
AL
PA R : 6 0 8
600
T+
T-
0 5 . 0 4
DC volta g e ref src
Analo g input 1 mon
Value:
T+
T-
EN
LOC
0 4 . 0 3
E
Access mode
p
Ex ert
Value
ILim
n:0
AL
T+
T-
EN
PA R :
5 5 0
0 4 . 0 1
Save arameters
p
Done
EN
LOC
ILim
n:0
AL
PA R : 6 0 8
5008
EN
LOC
ILim
n:0
AL
PA R : 6 0 8
1500
ILim
n:0
AL
PA R :
5 5 4
1
LOC
ILim
n:0
AL
PA R :
5 5 0
63

Advertisement

Table of Contents