LEDS
Colour
≤ F (*)
≥ L (*)
H11
D127
Red
H15
D131
Red
H18
D91
Red
D71
Red
D148
Red
D152
Green
D74
Green Active PWM to power
(*) HW revision of INT-P-ADV card
200
It lights up to indicate overtemperature of the air inside the drive
It lights up in case of overtemperature of one of the IGBT devices.
The signal temperature relating to the hotter of the master and slave
IGBT devices is sent to the regulation card.
A temperature signal is also sent automatically to the regulation card in
case of minimum temperature, which could occur in the event of a fault
in one of the temperature reading circuits.
The loss of one of the temperature signals is indicated by LED H15
(D131), with the code indicated by the number of flashes (*): the
sequence of flashes to indicate the faulty PHASE or SLAVE has a 3Hz
frequency and is repeated cyclically every 5 seconds.
It lights up on the INT-P-ADV MASTER card to indicate that the drive's
total current (master + slave) has exceeded the overcurrent value for
the size of drive, whereas it lights up on the INT-P-ADV SLAVE card to
indicate that the SLAVE current has only exceeded the overcurrent value
of the SLAVE.
Overvoltage / Undervoltage safety supply
FPGA active reset HW
Active PWM from regulation and sent to power (master drive or single
drive only)
(*) Led H15 (D131) code indicated by number of flashes
PHASE U
PHASE V
PHASE W
SLAVE 1
SLAVE 2
SLAVE 3
SLAVE 4
AFE200 • Instruction Manual
FUNCTION
OPERATIONS
Normal
functioning
Off
Off
Off
Off
On
On
On
NO. FLASHES
1
2
3
4
5
6
7

Advertisement