This parameter is used to disable the alarm at power-off by connecting the "FL fault
enable src" parameter to "Enable state mon".
Menu
PAR
Description
14.8.7
5730
FL Fwd 1 src
14.8.8
5732
FL Fwd 2 src
14.8.9
5734
FL Fwd 3 src
14.8.10 5736
FL Fwd 4 src
This parameter is used to select the origin (source) of the FL Fw 1 src signal.
The signal to be associated with this function can be selected from the "L_FLWORD"
selection list.
On the drive configured as the master, these parameters are used to select the data to
be sent to the first slave.
On drives configured as slaves, these paramters are used to select the data that the
slave must include in the data frame to replace the data received from the previous
drive.
Replacement is disabled in the default configuration. It can be enabled with the PAR
5712 "FL N Fwd slave chg" parameter.
Menu
PAR
Description
14.8.11 5830
FL Rev 1 src
14.8.12 5832
FL Rev 2 src
Parameter significant only for Slave drive, indicates what data to insert in first word to
be sent to Master drive when Slave is interrogated. Selectable values are shown on
the L_FLWORD list.
Menu
PAR
Description
14.8.13 5750
FL Fwd 1 mon
14.8.14 5752
FL Fwd 2 mon
14.8.15 5754
FL Fwd 3 mon
14.8.16 5756
FL Fwd 4 mon
14.8.17 5758
FL Fwd 5 mon
14.8.18 5760
FL Fwd 6 mon
14.8.19 5762
FL Fwd 7 mon
14.8.20 5764
FL Fwd 8 mon
These parameters are not used on the master drive.
On the slave drive these parameters show the value received from the previous drive.
The "Inv" parameters enable the value received to be used with the opposite sign,
without changing any of the data sent to subsequent slaves.
These parameters are available in the src analog parameter selection lists.
Menu
PAR
Description
14.8.21 5850
FL Rev 1 mon
14.8.22 5852
FL Rev 2 mon
14.8.23 5854
FL Rev 3 mon
138
UM
Type
FB BIT
LINK
16/32BIT 6000
LINK
16/32BIT 6000
LINK
16/32BIT 6000
LINK
16/32BIT 6000
L�FLWORD
UM
Type
FB BIT
LINK
16/32BIT 6000
LINK
16/32BIT 6000
L�FLWORD
UM
Type
FB BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
UM
Type
FB BIT
INT32
32BIT
INT32
32BIT
INT32
32BIT
AFE200 • Instruction Manual
Def
Min
0
0
0
0
Def
Min
0
0
Def
Min
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Def
Min
0
0
0
0
0
0
Max
Acc
16384 ERW
16384 ERW
16384 ERW
16384 ERW
Max
Acc
16384 ERW
16384 ERW
Max
Acc
0
ER
0
ER
0
ER
0
ER
0
ER
0
ER
0
ER
0
ER
Max
Acc
0
ER
0
ER
0
ER