Emerson Rosemount Ultrasonic 100 Series Manual
Emerson Rosemount Ultrasonic 100 Series Manual

Emerson Rosemount Ultrasonic 100 Series Manual

Option board field

Advertisement

Quick Links

Installation Procedure
00809-0100-3105, Rev AA
February 2022
Rosemount
Ultrasonic Series 100 Option
Board Field

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rosemount Ultrasonic 100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson Rosemount Ultrasonic 100 Series

  • Page 1 Installation Procedure 00809-0100-3105, Rev AA February 2022 ™ Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 2 Emerson employees. Emerson will not accept your returned equipment if you fail to follow Emerson procedures. Return procedures and forms are available on our web support site at Emerson.com, or by phoning the Emerson Customer Service department.
  • Page 3: Table Of Contents

    Installation Procedure Contents 00809-0100-3105 February 2022 Contents Part I Plan Chapter 1 Introduction......................7 1.1 General information of this document..................7 1.2 Requirements to start........................7 Part II Install Chapter 2 Installation of the Option Board................13 2.1 Instructions before opening the unit..................13 2.2 Instructions to install the Option Board..................13 Appendix A Engineering Drawings....................23...
  • Page 4 Contents Installation Procedure February 2022 00809-0100-3105 Emerson.com/Rosemount...
  • Page 5: Part I Plan

    Installation Procedure Plan 00809-0100-3105 February 2022 Part I Plan Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 6 Plan Installation Procedure February 2022 00809-0100-3105 Emerson.com/Rosemount...
  • Page 7: Chapter 1 Introduction

    Installation Procedure Introduction 00809-0100-3105 February 2022 Introduction General information of this document Welcome to the Rosemount Ultrasonic Series 100 Option Boards Field Installation Procedure manual. This manual has been designed to provide you with a step-by-step set of instructions for installing one of the Series 100 Option boards.
  • Page 8 Option Board Feature keys will be supplied by a Customer Service Representative for kits including keys for Ethernet, Archive Logs, AGA 10, and GC Master. 1.2.2 Required tools A. 1/8" flat-blade screw B. Phillips-head screw driver C. 11/32" hex driver Emerson.com/Rosemount...
  • Page 9 Installation Procedure Introduction 00809-0100-3105 February 2022 • Ground strap Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 10 Introduction Installation Procedure February 2022 00809-0100-3105 Emerson.com/Rosemount...
  • Page 11: Part Ii Install

    Installation Procedure Install 00809-0100-3105 February 2022 Part II Install Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 12 Install Installation Procedure February 2022 00809-0100-3105 Emerson.com/Rosemount...
  • Page 13: Installation Of The Option Board

    Installation Procedure Installation of the Option Board 00809-0100-3105 February 2022 Installation of the Option Board Instructions before opening the unit To prevent electrostatic damage to the electronic boards, always use a Ground Strap while handling the circuit boards. If one is not available, make sure you are electrically discharged before touching the boards by first touching a metal surface such as a ground lug on the meter or a table.
  • Page 14 Download utility open will display a complete help topic on how to perform the download. 2. Remove power to the unit and remove both end caps from the upper electronics. 3. Push the locking mechanism on both card guides to the unlocked position as shown. Emerson.com/Rosemount...
  • Page 15 Installation Procedure Installation of the Option Board 00809-0100-3105 February 2022 Figure 2-2: Unlock CPU board 4. Slide the CPU board out of the enclosure. Use the 1/8" flat-head or flat-blade screwdriver to unscrew the two Acquisition board cable screws. Disconnect the cable and remove the CPU board from the enclosure.
  • Page 16 Installation of the Option Board Installation Procedure February 2022 00809-0100-3105 Figure 2-4: Prepare Option board Emerson.com/Rosemount...
  • Page 17 Installation Procedure Installation of the Option Board 00809-0100-3105 February 2022 Figure 2-5: Option Board Connectors/Switches/LEDs Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 18 7. Install the Option board on the CPU board making sure that the connector on the bottom of the Option board mates to the connector on top of the CPU board. Figure 2-7: Mount Option board 8. Secure the Option board to the CPU board with the three Kep screws. Emerson.com/Rosemount...
  • Page 19 Installation Procedure Installation of the Option Board 00809-0100-3105 February 2022 Figure 2-8: Secure Option board 9. If the Wiring Diagram Card C-15470 attached to the enclosure is older than the one provided in the Option Board Kit, replace it with the newer revision. a) Use a hex driver to remove the nut that attaches the Wiring Diagram Card.
  • Page 20 Figure 2-10: Attach acquisition cable to CPU board 11. Slide the CPU board back onto the card guides and seat it in the Field Connection board. Push the locking mechanism on both card guides to the Locked position as Emerson.com/Rosemount...
  • Page 21 Installation Procedure Installation of the Option Board 00809-0100-3105 February 2022 shown to secure the CPU board. If the mechanisms do not move over, make sure the CPU board is fully seated in the enclosure and try again. Figure 2-11: Secure the CPU board 12.
  • Page 22 Installation of the Option Board Installation Procedure February 2022 00809-0100-3105 Figure 2-12: Install plugs 13. Reinstall the end caps on each end of the upper electronics enclosure. a) Reapply power to the unit. Figure 2-13: Install end caps Emerson.com/Rosemount...
  • Page 23: Appendix A Engineering Drawings

    Installation Procedure Engineering Drawings 00809-0100-3105 February 2022 Engineering Drawings DE-21056 Mark III Ultrasonic System Wiring, Ultrasonic Flowmeter Model 3400, 3410 and 3420 (Sheets 1-3) Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 24 Engineering Drawings Installation Procedure February 2022 00809-0100-3105 Mark III Ultrasonic System Wiring, Ultrasonic Flowmeter Model 3400, 3410 and 3420 (DE-21056) Emerson.com/Rosemount...
  • Page 25 Installation Procedure Engineering Drawings 00809-0100-3105 February 2022 Mark III Ultrasonic System Wiring, Ultrasonic Flowmeter Model 3400, 3410 and 3420 (DE-21056) Mark III Ultrasonic System Wiring, Ultrasonic Flowmeter Model 3400, 3410 and 3420 (DE-21056) Rosemount Ultrasonic Series 100 Option Board Field...
  • Page 26 2022 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property...

Table of Contents