Monitor Modes - YASKAWA E-V Series User Manual

Ac servodrive, linear motor, communications reference
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

9.2

Monitor Modes

The following list shows monitor modes available.
Parameter
No.
Un000
Motor moving speed
Un001
Speed reference
Un002
Internal force reference (in percentage to the rated force)
Un003
Electric angle 1 (32-bit decimal code)
Un004
Electric angle 2 (Electric angle from the origin)
Un005
Input signal monitor
Un006
Output signal monitor
Un007
Input reference speed (valid only in position control)
Un008
Error counter (position error amount) (valid only in position control)
Accumulated load ratio (in percentage to the rated force:
Un009
effective force in cycle of 10 seconds)
Regenerative load ratio (in percentage to the processable regenerative power:
Un00A
regenerative power consumption in cycle of 10 seconds)
Power consumed by DB resistance
Un00B
(in percentage to the processable power at DB activation: displayed in cycle
of 10 seconds)
Un00C
Input reference counter (decimal, 10-digit display)
Feedback pulse counter (encoder pulses × 4 (multiplier): 32-bit decimal
Un00D
code)
Un011
Hall sensor signal monitor
Un012
Total operation time
Un013
Feedback pulse counter (decimal, 10-digit display)
Un014
Effective gain monitor
Un015
Safety I/O signal monitor
Un020
Motor rated speed
Un021
Motor maximum speed
Un084
Linear scale pitch
Un085
Linear scale pitch index
Content of Display

9.2 Monitor Modes

Unit
mm/s
mm/s
%
pulses from the origin
deg
mm/s
reference unit
%
%
%
reference unit
encoder pulse
100 ms
reference unit
mm/s
mm/s
pm
exponential in decimal
9-33
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents