YASKAWA E-V Series User Manual page 114

Ac servodrive, linear motor, communications reference
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

Adjustment Function Restriction
Adjustment Function
One-parameter tuning (Fn203)
EasyFFT (Fn206)
Initialize vibration detection level
(Fn01B)
Advanced autotuning (Fn201)
Advanced autotuning by reference
(Fn202)
Anti-resonance control adjustment
function (Fn204)
Vibration suppression function (Fn205)
Offline mass calculating *
Mechanical analysis *
Operate using SigmaWin+.
(3) Automatically Setting the Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set.
Set this function to Not Auto Setting only if you do not change the notch filter setting before executing tuning-
less function.
Parameter
n. 0
Pn460
n. 1
(4) Tuning-less Level Settings (Fn200)
The tuning-less level is set in Fn200.
To ensure safety, always implement the tuning-less function in a state where an emergency stop is possible.
Available//Not available
Not available
Available
Available
Available
Not available
Not available
Not available
Not available
Available
Meaning
Does not set the 2nd notch filter automatically.
Sets the 2nd notch filter automatically.
[Factory setting]
CAUTION
5.2 Tuning-less Function
Remarks
While this function is being used, the tuning-
less function cannot be used temporarily.
• This function can be used when Jcalc is set
to ON.
• During or after use of this function, the
tuning-less function cannot be used.
While this function is being used, the tuning-
less function cannot be used temporarily.
When Enabled
Classification
Immediately
Tuning
5
5-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents