Parameter
Name
No.
Input Signal Selection 5
4th
3rd
2nd
digit
digit
digit
n.
Pn511
Setting
Range
0000 to FFFF
1st
digit
/DEC (Deceleration limit switch for homing) Signal Mapping
0
Inputs the signal from CN1-13 input terminal.
1
Inputs the signal from CN1-7 input terminal.
2
Inputs the signal from CN1-8 input terminal.
3
Inputs the signal from CN1-9 input terminal.
4
Inputs the signal from CN1-10 input terminal.
5
Inputs the signal from CN1-11 input terminal.
6
Inputs the signal from CN1-12 input terminal.
7
Sets signal ON.
8
Sets signal OFF.
9
Inputs the reversal signal from CN1-13 input terminal.
A
Inputs the reversal signal from CN1-7 input terminal.
B
Inputs the reversal signal from CN1-8 input terminal.
C
Inputs the reversal signal from CN1-9 input terminal.
D
Inputs the reversal signal from CN1-10 input terminal.
E
Inputs the reversal signal from CN1-11 input terminal.
F
Inputs the reversal signal from CN1-12 input terminal.
/EXT1 (External latch) Signal Mapping
4
Inputs the signal from CN1-10 input terminal.
5
Inputs the signal from CN1-11 input terminal.
6
Inputs the signal from CN1-12 input terminal.
7
Sets signal ON.
8
Sets signal OFF.
D
Inputs the reversal signal from CN1-10 input terminal.
E
Inputs the reversal signal from CN1-11 input terminal.
F
Inputs the reversal signal from CN1-12 input terminal.
0 to 3
Sets signal OFF.
9 to F
/EXT2 (External latch 2) Signal Mapping
0 to F
Refer to /EXT1 signal mapping.
/EXT3 (External latch 3) Signal Mapping
0 to F
Refer to /EXT1 signal mapping.
Factory