Step
D o n e
V i b r a t i o n D e t e c t
4
D o n e
R U N
F n 0 1 4 : O p t I n i t
5
F n 0 1 B : V i b l − v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
(2) Related Parameters
Use the following parameters as required.
Vibration Detection Sensibility
Pn311
Setting Range
50 to 500
Vibration Detection Level
Pn384
Setting Range
0 to 5000
Note: Pn384 is set by the vibration detection level, so it is not necessary to adjust it.
The vibration detection sensibility can be set at Pn311.
Parameter
Pn310
Display Example
L e v e l
I n i t
− F U N C T I O N −
Setting Unit
1%
Setting Unit
1 mm/s
n.
0
Does not detect vibration (Factory setting)
Outputs the warning (A.911) when vibration is
n.
1
detected.
n.
2
Outputs the alarm (A.520) when vibration is detected.
6.16 Vibration Detection Level Initialization (Fn01B)
Keys
Press the
Key. The display changes from "Init"
to "Done," and the setting becomes enabled.
Press the
key to return to the Utility Function
Mode main menu.
Speed
Position
 
Force
Factory Setting
100
Speed
Position
 
Force
Factory Setting
10
Meaning
Description
Classification
When Enabled
Immediately
Setup
Classification
When Enabled
Immediately
Setup
When Enabled Classification
Immediately
Setup
6
6-27