9.1.2 Parameters

Parameter
Name
No.
Basic Function Select Switch 0
4th
3rd
2nd
digit
digit
digit
n.
Pn000
Application Function Select Switch 1
4th
3rd
2nd
digit
digit
digit
n.
Pn001
Setting
Range
0000 to 00B3
1st
digit
Direction Selection
0
Sets the linear scale countiong up (phase-A lead) direction as forward direction.
1
Sets the linear scale countiong down (phase-B lead) direction as forward direction
(Reverse Movement Mode)
2 to 3
Reserved (Do not use.)
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 1122
1st
digit
Servo OFF or Alarm Gr.1 Stop Mode
Stops the motor by applying DB (dynamic brake).
0
Stops the motor by applying dynamic brake (DB) and then releases DB.
1
Makes the motor coast to a stop state without using the dynamic brake (DB).
2
Overtravel (OT) Stop Mode
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
0
Sets the force of Pn406 to the maximum value, decelerate the motor to a stop,
1
and then sets it to servolock state.
Sets the force of Pn406 to the maximum value, decelerates the motor to a stop,
2
and then sets it to coasting state.
AC/DC Power Input Selection
Not applicable to DC power input: Input AC power supply through L1, L2 (, and L3) terminals.
0
Applicable to DC power input: Input DC power supply between B1/ + and 2, or input
1
DC power supply between B1 and 2.
Reserved (Do not change.)
Factory
When
Units
Setting
Enabled
0000
After restart
0000
After restart
9.1 List of Parameters
Reference
Classification
Section
Setup
(Refer to 5.2.2.)
(Refer to 4.3.1)
Setup
(Refer to 4.3.3)
(Refer to 4.3.2)
(Refer to 3.1.5)
9