6.15 Resetting Configuration Error of Option Module (Fn014)

The SERVOPACK with option card recognizes installation status and types of option card which is connected
to SERVOPACK. If an error is detected, the SERVOPACK issues an alarm.
This function resets these alarms.
For alarm types and corrective actions, refer to 8 Troubleshooting.
Note 1. Alarms related to option cards can be cleared only this function. These alarms cannot be cleared by alarm reset or
turning OFF the main circuit power supply.
2. Before clearing the alarm, perform corrective action for the alarm.
(1) Operating Procedure
Follow the steps below.
Step
Display Example
R U N
F n 0 1 3 : M t u r n L m S e t
1
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l − v l I n i t
F n 0 1 E : S v M o t O p I D
B B
C o m m a n d O p t
2
S t a r t
R e t u r n : [ S E T ]
D O N E
C o m m a n d O p t
3
S t a r t
R e t u r n : [ S E T ]
R U N
F n 0 1 3 : M t u r n L m S e t
5
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l − v l I n i t
F n 0 1 E : S v M o t O p I D
6
Turn OFF the power and then turn it ON again to validate the new setting.
− F U N C T I O N −
− O p t I n i t −
I n i t i a l i z e
: [ D A T A ]
− O p t I n i t −
I n i t i a l i z e
: [ D A T A ]
− F U N C T I O N −

6.15 Resetting Configuration Error of Option Module (Fn014)

Keys
Press the
or
press the
key.
Press the
Key to select an option card to be
cleared.
Note: If the display is not switched and "NO-OP" is
displayed in the status display, the Write Prohib-
ited Setting (Fn010 = 0001) is set. Check the
setting and reset.
Press the
Key to clear the configuration error of
the option card.
Press the
key to return to the Utility Function
Mode main menu.
Description
Key to select Fn014. Then,
6