6 Utility Functions (Fn
(2) Operating Procedure
Follow the steps below to set
Setting values are as follows:
0000
"
0001
"
Step
1
2
3
4
5
6
6-22
)
write prohibited
"
: Write permitted (Releases write prohibited mode.)
"
: Write prohibited (Parameters become write prohibited from the next power ON.)
"
Display Example
− F U N C T I O N −
B B
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 0
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
D o n e
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
B B
− F U N C T I O N −
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
Turn OFF the power and then turn it ON again to validate the new setting.
or
write permitted.
"
"
"
Keys
Press the
main menu and select Fn010.
Press the
The display switches to the execution display of
Fn010.
Press the
tings.
0000: Write permitted
0001: Write prohibited
Press the
the SERVOPACK, and the status display changes as
follows: "BB" to "Done" to "A.941.*"
∗ "A.941" means that setting validation is required to
validate the new settings.
Press the
Mode main menu.
Description
Key to open the Utility Function Mode
Key.
Key to select one of the following set-
Key. The setting value is written into
Key to return to the Utility Function