Cleaning The Fan Unit - ABB DressPack Product Manual

Table of Contents

Advertisement

3.4.3 Cleaning the Fan unit

Overview
Use this section to clean the fan unit.
Location
en0500001924
A
B
C
Required equipment
Equipment
Standard toolkit
DressPack/SpotPack
Vacuum cleaner
Maintenance procedure
1
2
3
Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B
Fan holder with fan
Fan casing
Attachment screws M5x9, Fastite screw (4 pcs)
Action
DANGER
Before any work inside the cabinet, please
observe the safety information in the sec-
tion DANGER - Make sure that the main
power has been switched off in the product
manual for the IRC5 controller.
Remove the attachment screws holding the
fan casing.
Disconnect the fan connector.
© Copyright 2015-2017 ABB. All rights reserved.
Article number
Note
3HAC17290-7
The contents are defined in section
Toolkits, DressPack/SpotPack on
page
-
Note
Shown in the section
Screw M5x9 Fastite (4 pcs)
3 Maintenance
3.4.3 Cleaning the Fan unit
233.
Location on page 151
Continues on next page
151